เวลาให้บริการ: วันจันทร์ถึงวันศุกร์ 9:00-18:00 น.
HC-HS 2-D7-EBUS - HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert
มีสินค้าพร้อมส่ง สินค้าขายดี

HC-HS 2-D7-EBUS

HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert

$35.46 ดอลลาร์สหรัฐ
มีสินค้าในสต็อก
ข้อมูลจำเพาะหลัก
: Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
พิมพ์: D7
การทดสอบ: DIN VDE 0627/86
ความกว้าง: 21 mm
ข้อมูลผู้จำหน่าย
ผลิตภัณฑ์: 0
โดยปกติจะจัดส่งภายใน 2-3 วันทำการ
รับประกันคุณภาพ
จัดส่งรวดเร็ว
ฝ่ายสนับสนุนด้านเทคนิค

ข้อกำหนดทางเทคนิค

พารามิเตอร์ ค่า
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
พิมพ์ D7
การทดสอบ DIN VDE 0627/86
ความกว้าง 21 mm
ความสูง 34.8 mm
ความยาว 21 mm
ชุด HC-HS
ทั่วไป for HC-D7 housing, axial connection 2.0 mm, Allen key
แอปพลิเคชัน Power
ประเภทผลิตภัณฑ์ Contact insert with a fixed no. of positions
หมายเหตุประกอบการประกอบ To ensure correct use, installation in housing with IP54 protection or better is required
กระแสไฟฟ้าที่กำหนด 40 A
การแก้ไขบทความ 04
เส้นผ่านศูนย์กลางสัมผัส 4 mm
วัสดุติดต่อ Copper alloy
ซ็อกเก็ตหกเหลี่ยม SW2,0
หมายเลขติดต่อ 1 - 2
แรงบิดในการขัน 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
โปรไฟล์การเชื่อมต่อ 2+PE
ระดับมลพิษ 3
ภาพวาดแสดงขนาด
จำนวนตำแหน่ง 2
แรงดันไฟกระชากที่กำหนด 6 kV
หมวดหมู่แรงดันไฟเกิน III
เทคโนโลยีการเชื่อมต่อ Axial screw connection
ประเภทวัสดุสัมผัส turned
จำนวนขั้วต่อไฟฟ้า 2
แรงดันไฟฟ้าที่กำหนด (III/3) 400 V
หน้าตัดตัวนำ 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
วัสดุตัวนำสัมผัส PC
วัสดุพื้นผิวสัมผัส Ag
รอบการใส่/ถอด ≥ 500
หน้าตัดการเชื่อมต่อ AWG 10 ... 8
อุณหภูมิแวดล้อม (ขณะใช้งาน) -40 °C ... 125 °C (including heating up of contacts)
การเชื่อมต่อตามมาตรฐาน IEC / EN
ข้อบังคับด้านการก่อสร้างและการทดสอบ DIN VDE 0627/86
ระดับความไวไฟตามมาตรฐาน UL 94 V0
ความยาวในการลอกฉนวนของสายไฟแต่ละเส้น 8 mm +1 mm

คำอธิบายผลิตภัณฑ์

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
คุณสมบัติหลัก
  • คุณภาพระดับอุตสาหกรรม
  • เป็นไปตามมาตรฐาน RoHS
  • ได้รับการรับรอง CE
  • รับประกัน 1 ปี

เอกสารผลิตภัณฑ์

เอกสารข้อมูลทางเทคนิค

ข้อมูลจำเพาะทางเทคนิคและข้อมูลประสิทธิภาพ

คู่มือผู้ใช้

คู่มือการติดตั้งและการใช้งาน

Top